251 research outputs found

    In-situ comparison of the NOy instruments flown in MOZAIC and SPURT

    Get PDF
    Two aircraft instruments for the measurement of total odd nitrogen (NOy) were compared side by side aboard a Learjet A35 in April 2003 during a campaign of the AFO2000 project SPURT (Spurengastransport in der Tropopausenregion). The instruments albeit employing the same measurement principle (gold converter and chemiluminescence) had different inlet configurations. The ECO-Physics instrument operated by ETH-ZĂŒrich in SPURT had the gold converter mounted outside the aircraft, whereas the instrument operated by FZ-JĂŒlich in the European project MOZAIC III (Measurements of ozone, water vapour, carbon monoxide and nitrogen oxides aboard Airbus A340 in-service aircraft) employed a Rosemount probe with 80 cm of FEP-tubing connecting the inlet to the gold converter. The NOy concentrations during the flight ranged between 0.3 and 3 ppb. The two data sets were compared in a blind fashion and each team followed its normal operating procedures. On average, the measurements agreed within 7%, i.e. within the combined uncertainty of the two instruments. This puts an upper limit on potential losses of HNO3 in the Rosemount inlet of the MOZAIC instrument. Larger transient deviations were observed during periods after calibrations and when the aircraft entered the stratosphere. The time lag of the MOZAIC instrument observed in these instances is in accordance with the time constant of the MOZAIC inlet line determined in the laboratory for HNO3

    Low-dose intranasal versus oral midazolam for routine body MRI of claustrophobic patients

    Get PDF
    The purpose of this study was to assess prospectively the potential of low-dose intranasal midazolam compared to oral midazolam in claustrophobic patients undergoing routine body magnetic resonance imaging (MRI). Seventy-two adult claustrophobic patients referred for body MRI were randomly assigned to one of two treatment groups (TG1 and TG2). The 36 patients of TG1 received 7.5mg midazolam orally 15min before MRI, whereas the 36 patients of TG2 received one (or, if necessary, two) pumps of a midazolam nasal spray into each nostril immediately prior to MRI (in total, 1 or 2mg). Patients' tolerance, anxiety and sedation were assessed using a questionnaire and a visual analogue scale immediately before and after MRI. Image quality was evaluated using a five-point-scale. In TG1, 18/36 MRI examinations (50%) had to be cancelled, the reduction of anxiety was insufficient in 12/18 remaining patients (67%). In TG2, 35/36 MRI examinations (97%) were completed successfully, without relevant adverse effects. MRI image quality was rated higher among patients of TG2 compared to TG1 (p<0.001). Low-dose intranasal midazolam is an effective and patient-friendly solution to overcome anxiety in claustrophobic patients in a broad spectrum of body MRI. Its anxiolytic effect is superior to that of the orally administrated for

    Comparable Analysis of Acute Changes in Vascular Tone after Coffee versus Energy Drink Consumption

    Get PDF
    Caffeinated beverages are popular throughout the world, especially due to their stimulating effects on body physiology. However, short- and long-term outcome studies have shown variable results on general health. In this pilot study, we exposed a cohort of 23 healthy individuals to 240 mg of caffeine either in the form of coffee or energy drinks and performed repetitive pulse wave analyses. This experimental approach was chosen to investigate the acute effects of caffeine consumption on vascular tone depending on the form of caffeine intake. Our data indicate that energy drinks, in contrast to coffee, might negatively impact systolic blood pressure and pulse wave velocity. This issue needs special attention in the light of cardiovascular health as the observed effects have been associated with an increased risk of cardiovascular events upon persistent exposure

    Lagrangian Particle Dispersion Models in the Grey Zone of Turbulence: Adaptations to FLEXPART-COSMO for Simulations at 1 km Grid Resolution.

    Get PDF
    Lagrangian particle dispersion models (LPDMs) are frequently used for regional-scale inversions of greenhouse gas emissions. However, the turbulence parameterizations used in these models were developed for coarse resolution grids, hence, when moving to the kilometre-scale the validity of these descriptions should be questioned. Here, we analyze the influence of the turbulence parameterization employed in the LPDM FLEXPART-COSMO model. Comparisons of the turbulence kinetic energy between the turbulence schemes of FLEXPART-COSMO and the underlying Eulerian model COSMO suggest that the dispersion in FLEXPART-COSMO suffers from a double-counting of turbulent elements when run at a high resolution of . Such turbulent elements are represented in both COSMO, by the resolved grid-scale winds, and FLEXPART, by its stochastic parameterizations. Therefore, we developed a new parametrization for the variations of the winds and the Lagrangian time scales in FLEXPART in order to harmonize the amount of turbulence present in both models. In a case study for a power plant plume, the new scheme results in improved plume representation when compared with in situ flight observations and with a tracer transported in COSMO. Further in-depth validation of the LPDM against methane observations at a tall tower site in Switzerland shows that the model's ability to predict the observed tracer variability and concentration at different heights above ground is considerably enhanced using the updated turbulence description. The high-resolution simulations result in a more realistic and pronounced diurnal cycle of the tracer concentration peaks and overall improved correlation with observations when compared to previously used coarser resolution simulations (at 7 km 7 km). Our results indicate that the stochastic turbulence schemes of LPDMs, developed in the past for coarse resolution models, should be revisited to include a resolution dependency and resolve only the part of the turbulence spectrum that is a subgrid process at each different mesh size. Although our new scheme is specific to COSMO simulations at resolution, the methodology for deriving the scheme can easily be applied to different resolutions and other regional models. Supplementary Information The online version contains supplementary material available at 10.1007/s10546-022-00728-3

    Effect of Hyperventilation on Periodic Repolarization Dynamics

    Get PDF
    Heart and lung functions are closely connected, and the interaction is mediated by the autonomic nervous system. Hyperventilation has been demonstrated to especially activate its sympathetic branch. However, there is still a lack of methods to assess autonomic activity within this cardiorespiratory coupling. Periodic repolarization dynamics (PRD) is an ECG-based biomarker mirroring the effect of efferent cardiac sympathetic activity on the ventricular myocardium. Its calculation is based on beat-to-beat variations of the T wave vector (dT degrees). In the present study, we investigated the effects of a standardized hyperventilation maneuver on changes of PRD and its underlyingdT degrees signal in 11 healthy subjects. In response to hyperventilation,dT degrees revealed a characteristic pattern and normalizeddT degrees values increased significantly compared to baseline [0.063 (IQR 0.032) vs. 0.376 (IQR 0.093),p< 0.001] and recovery [0.082 (IQR 0.029) vs. 0.376 (IQR 0.093),p< 0.001]. During recovery,dT degrees remained on a higher level compared to baseline (p= 0.019). When calculating PRD, we found significantly increased PRD values after hyperventilation compared to baseline [3.30 (IQR 2.29) deg(2)vs. 2.76 (IQR 1.43) deg(2),p= 0.018]. Linear regression analysis revealed that the increase in PRD level was independent of heart rate (p= 0.63). Our pilot data provide further insights in the effect of hyperventilation on sympathetic activity associated repolarization instability

    Estimation of anaerobic threshold by cardiac repolarization instability: a prospective validation study

    Get PDF
    BACKGROUND Assessing lactate (LT) or anaerobic thresholds (AT) in athletes is an important tool to control training intensities and to estimate individual performance levels. Previously we demonstrated that ECG-based assessment of cardiac repolarization instability during exercise testing allows non-invasive estimation of AT in recreational athletes. Here, we validate this method in professional and amateur team sports athletes. METHODS We included 65 team sports athletes (32 professionals and 33 amateur athletes; 51 men, 14 women, mean age 22.3 ± 5.2 years) undergoing a standardized incremental cycle exercise test. During exercise testing a high-resolution ECG (1000~Hz) was recorded in Frank-leads configuration and beat-to-beat vector changes of cardiac repolarization (dT°) were assessed by previously established technologies. Repolarization-based AT (ATdT°) was estimated by its typical dT°-signal pattern. Additionally, LT was detected in accordance to methods established by Mader (LTMader) and Dickhuth (LTDickhuth). RESULTS All athletes performed exercise testing until exhaustion with a mean maximum workload of 262.3 ± 60.8~W (241.8 ± 64.4~W for amateur athletes and 283.4 ± 49.5~W for professional athletes). Athletes showed ATdT° at 187.6 ± 44.4~W, LTDickhuth at 181.1 ± 45.6~W and LTMader at 184.3 ± 52.4~W. ATdT° correlated highly significantly with LTDickhuth (r = 0.96, p < 0.001) and LTMader (r = 0.98, p < 0.001) in the entire cohort of athletes as well as in the subgroups of professional and amateur athletes (p < 0.001 for all). CONCLUSIONS ATdT°, defined by the maximal discordance between dT° and heart rate, can be assessed reliably and non-invasively via the use of a high-resolution ECG in professional and amateur athletes

    Three-dimensional radiative transfer effects on airborne and ground-based trace gas remote sensing

    Get PDF
    Air mass factors (AMFs) are used in passive trace gas remote sensing for converting slant column densities (SCDs) to vertical column densities (VCDs). AMFs are traditionally computed with 1D radiative transfer models assuming horizontally homogeneous conditions. However, when observations are made with high spatial resolution in a heterogeneous atmosphere or above a heterogeneous surface, 3D effects may not be negligible. To study the importance of 3D effects on AMFs for different types of trace gas remote sensing, we implemented 1D-layer and 3D-box AMFs into the Monte carlo code for the phYSically correct Tracing of photons In Cloudy atmospheres (MYSTIC), a solver of the libRadtran radiative transfer model (RTM). The 3D-box AMF implementation is fully consistent with 1D-layer AMFs under horizontally homogeneous conditions and agrees very well ( < 5 % relative error) with 1D-layer AMFs computed by other RTMs for a wide range of scenarios. The 3D-box AMFs make it possible to visualize the 3D spatial distribution of the sensitivity of a trace gas observation, which we demonstrate with two examples. First, we computed 3D-box AMFs for ground-based multi-axis spectrometer (MAX-DOAS) observations for different viewing geometry and aerosol scenarios. The results illustrate how the sensitivity reduces with distance from the instrument and that a non-negligible part of the signal originates from outside the line of sight. Such information is invaluable for interpreting MAX-DOAS observations in heterogeneous environments such as urban areas. Second, 3D-box AMFs were used to generate synthetic nitrogen dioxide (NO2) SCDs for an air-borne imaging spectrometer observing the NO2 plume emitted from a tall stack. The plume was imaged under different solar zenith angles and solar azimuth angles. To demonstrate the limitations of classical 1D-layer AMFs, VCDs were then computed assuming horizontal homogeneity. As a result, the imaged NO2 plume was shifted in space, which led to a strong underestimation of the total VCDs in the plume maximum and an underestimation of the integrated line densities that can be used for estimating emissions from NO2 images. The two examples demonstrate the importance of 3D effects for several types of ground-based and airborne remote sensing when the atmosphere cannot be assumed to be horizontally homogeneous, which is typically the case in the vicinity of emission sources or in cities

    Quantification of methane emissions from UK biogas plants

    Get PDF
    The rising number of operational biogas plants in the UK brings a new emissions category to consider for methane monitoring, quantification and reduction. Minimising methane losses from biogas plants to the atmosphere is critical not only because of their contribution of methane to global warming but also with respect to the sustainability of renewable energy production. Mobile greenhouse gas surveys were conducted to detect plumes of methane emissions from the biogas plants in southern England that varied in their size, waste feed input materials and biogas utilization. Gaussian plume modelling was used to estimate total emissions of methane from ten biogas plants based on repeat passes through the plumes. Methane emission rates ranged from 0.1 to 58.7 kg CH4 hr-1, and the percentage of losses relative to the calculated production rate varied between 0.02 and 8.1%. The average emission rate was 15.9 kg CH4 hr-1, and the average loss was 3.7%. In general, methane emission rates from smaller farm biogas plants were higher than from larger food waste biogas plants. We also suggest that biogas methane emissions may account for between 0.4 and 3.8%, with an average being 1.9% of the total methane emissions in the UK excluding the sewage sludge biogas plants

    Zugang zu non-formalen Weiterbildungsmöglichkeiten der digitalen Kompetenzen fĂŒr Erwachsene in Österreich.

    Get PDF
    In dieser multimethodischen, qualitativen Studie werden non-formale Weiterbildungsmöglichkeiten der digitalen Kompetenzen fĂŒr Erwachsene in Österreich beforscht. Entlang der Dimensionen des DigComp 2.2 AT soll das Angebot in diesem Bereich identifiziert werden bzw. eine Agenda fĂŒr den weiteren Ausbau des Angebots bzw. die weitere Beforschung skizziert werden.In this multimethod qualitative study, non-formal opportunities for further education in the context of digital competences are researched. The focus lies on Austrian adults. Along the dimensions of DigComp 2.2 AT, the offering in this area is to be identified and an agenda for the further expansion of the offering or further research is to be outlined

    Spatial and temporal representativeness of point measurements for nitrogen dioxide pollution levels in cities

    Get PDF
    In many cities around the world the overall air quality is improving, but at the same time nitrogen dioxide (NO2) trends show stagnating values and in many cases could not be reduced below air quality standards recommended by the World Health Organization (WHO). Many large cities have built monitoring stations to continuously measure different air pollutants. While most stations follow defined rules in terms of measurement height and distance to traffic emissions, the question remains of how representative are those point measurements for the city-wide air quality. The question of the spatial coverage of a point measurement is important because it defines the area of influence and coverage of monitoring networks, determines how to assimilate monitoring data into model simulations or compare to satellite data with a coarser resolution, and is essential to assess the impact of the acquired data on public health. In order to answer this question, we combined different measurement data sets consisting of path-averaging remote sensing data and in situ point measurements in stationary and mobile setups from a measurement campaign that took place in Munich, Germany, in June and July 2016. We developed an algorithm to strip temporal from spatial patterns in order to construct a consistent NO2 pollution map for Munich. Continuous long-path differential optical absorption spectroscopy (LP DOAS) measurements were complemented with mobile cavity-enhanced (CE) DOAS, chemiluminescence (CL) and cavity attenuated phase shift (CAPS) instruments and were compared to monitoring stations and satellite data. In order to generate a consistent composite map, the LP DOAS diurnal cycle has been used to normalize for the time of the day dependency of the source patterns, so that spatial and temporal patterns can be analyzed separately. The resulting concentration map visualizes pollution hot spots at traffic junctions and tunnel exits in Munich, providing insights into the strong spatial variations. On the other hand, this database is beneficial to the urban planning and the design of control measures of environment pollution. Directly comparing on-street mobile measurements in the vicinity of monitoring stations resulted in a difference of 48 %. For the extrapolation of the monitoring station data to street level, we determined the influence of the measuring height and distance to the street. We found that a measuring height of 4 m, at which the Munich monitoring stations measure, results in 16 % lower average concentrations than a measuring height of 1.5 m, which is the height of the inlet of our mobile measurements and a typical pedestrian breathing height. The horizontal distance of most stations to the center of the street of about 6 m also results in an average reduction of 13 % compared to street level concentration. A difference of 21 % in the NO2 concentrations remained, which could be an indication that city-wide measurements are needed for capturing the full range and variability of concentrations for assessing pollutant exposure and air quality in cities
    • 

    corecore